Showing results: 406 - 420 of 1305 items found.
-
TOB-SM8124 -
Xiamen Tob New Energy Technology Co., Ltd
200V 20 Ohm Portable Battery Tester For Battery Voltage and Resistance Testing. TOB-SM8124 Resistance Voltage Tester is a portable battery tester used for battery voltage and internal resistance test, it is Suitable for lithium-ion battery, nickel-metal hydride, lithium manganese, lead-acid battery and other single battery or battery pack with voltage no more than 200V.
-
SCR ELEKTRONIKS
Electrical Safety is the most primary and essential product conformity requirement for any product that uses electricity. The clauses of safety testing of electrical products laid by worldwide agencies such as UL, CE, BIS, etc. are stringent. The products need to pass through tests such as the high voltage test, insulation resistance test, earth bond test, leakage current test and so on. And to conform to such tests, SCR Elektroniks have developed for the testing of Geyser. In addition to the conventional safety tests, test for performance is also included.
-
4167 MF -
Standard Electric Works Co., Ltd
● High Quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Two insulation test voltages(DC) : 250V and 500V.● Alternation voltage measurement.● Battery life indicator.● Fuse protected.
-
Aero Nav Laboratories, Inc.
The electrical contact testing is performed to determine the reliability of equipment under various contacting conditions. A few types of electrical contact tests are: contact-chatter monitoring, contact resistance, intermediate, and low level contact switching.
-
Sanwood Environmental Chambers Co ., Ltd.
Drying Oven can provide a stable test space for pre-heating, drying, changes about physics and chemistry testing . It supplies precision temperature controller with high stability of platinum resistance to temperature that makes temperature well-distribution.
-
Sanwa Electric Instrument Co., Ltd
Is a spot insulation test which uses an applied DC voltage (typically either 250Vdc, 500Vdc or 1,000Vdc for low voltage equipment <600V and 2,500Vdc and 5,000Vdc for high voltage equipment) to measure insulation resistance.
-
MY3710HS -
MICRONIX
Higher shielding performance than MY371080dB. Suitable for weak electric field resistance test, out-of-service test or digital forensics for mobile phone, smart phone or tablet terminal! DUT can be operated directly with bare hands while placing it in the box and looking at the inside from the shield window.
-
LSD-01A -
Jinan Leading Instruments Co., Ltd.
LSD-01A Leak Tester is applicablein leak testing of pouches, bottles, pipes, cans and boxes of foodstuff,pharmaceutical, medical, daily chemistry, automotive, electronic components, stationary and other industries. It’ s also applicable in the leak testing ofthe specimens after falling tests and pressure resistance tests.
-
CX-15 -
Shenzhen Chuangxin Instruments Co., Ltd.
The Impact Test Ball is a specially machined ball to test impact resistance according to IEC, CSA and UL Standards. It is made of chrome-plated-steel for durability, and is fitted with an eyelet to facilitate testing for pendulum applications. Eyelet is threaded to the ball to allow attachment of a handle or force gauge. Weights are closely controlled.
-
ASTM D1781 -
National Technical Systems
This test method is used to compare adhesion between flexible and rigid adherents, or between flexible facing of a sandwich structure and its core. Comparisons of adhesives and processes are only applicable when test specimens and conditions are the same. The peel resistance may indicate degree of cure for relatively brittle adhesives.
-
AD-510 -
ADEX Urzadzenia Pomiarowe
Large, readable LCD display (2000 counts), Instant battery life indicator, Test frequency: 128 Hz (quartz generator), Test Voltage: max 30 V peak-to-peak, Range: 0,01 W ? 2 k W. Accuracy resistance measurement: 1 % 2 digits,
-
PRF-911PT -
Prostat Corporation
The PRF-911 Concentric Ring is to be attached to the PRS-801B Resistance System included in this Packaging Test Kit. This system will also give you surface resistivity by multiplying the surface resistance measurement in ohms by 10 to obtain surface resistivity in ohms/square. The PRF-911PT meets requirements from ANSI/ESD STM11.11, ANSI/ESD STM11.12 snd IEC 61340-2-3. It will also approximate surface and volume resistivity measurements per ASTM D-257.
-
19035 -
Chroma Systems Solutions, Inc.
The quality verification test items for Wound Components consist of AC/DC Hipot tests and Insulation Resistance (IR) tests. Chroma integrates the above tests into the Hybrid 19035 Wound Component EST Scanner series to perform safety tests for motor, transformer, and heater related wound products. The wound component manufacturers performing quality verification testing will not only have reliable quality, but also can control product quality efficiently.
-
Triplett Test Equipment & Tools
compact digital multimeter with a backlit LCD display. It offers a large variety of measurement features including AC/DC Voltage, DC Current, Resistance, Continuity, Diode Test, Transistor hFE, and Temperature. The rubberized boot provides impact and drop resistance in a sleek ergonomic design, and the user-friendly Auto Power Off feature helps maximizes battery life. The Model 1101-B is well suited for a variety of commercial and residential applications such as security, home theater, electrical, HVAC installations and more. Includes test leads with alligator clips, Type K bead probe and battery (9V).
-
PRS-812B -
Prostat Corporation
- Wide Range Resistance: 0.10 Ω to 1.00x1012 Ω- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Constant Test voltages 10V and 100V for specification measurements to meet international and domestic ESD measurement standards- Auto Resistance Range Control- Auto Test Voltage Control- Uses a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- 120 Data Set Internal Memory- Uses Standard USB Cable for Charging- Charges in 2 Hours- 2-year Limited Warranty on Main Instrument